Questions for the H13-611 were updated on : Dec 06 ,2025
Which statements are true about the ports of a Huawei OceanStor all-flash storage device? (Select All
that Apply)
AC
Explanation:
A and C are true statements about the ports of a Huawei OceanStor all-flash storage device. Bond
ports, VLANs, and logical ports are created based on available Ethernet ports, while multiple
Ethernet ports of the same controller are bonded to form a bond port to increase the bandwidth. The
networks and services between VLANs are physically isolated, which improves the security and
reliability of service data. Multiple logical ports can be created for a bond port, but only one logical
port can be created for an Ethernet port.
Which statements are true about a dual-controller storage system? (Select All that Apply)
AD
Explanation:
In active-standby mode, only one controller works at a time and if one controller is faulty, services
are not affected. In active-active mode, both controllers are active and the service failover is more
efficient than in active-standby mode.
Suppose, for cost control reasons, a startup company can acquire only one storage device to provide
services. However, its services require high hardware reliability, so an engineer recommended a
Huawei OceanStor all-flash storage system. Which statements describe the high reliability of the
storage system? (Select All that Apply)
ABD
Explanation:
The statements that describe the high reliability of the Huawei OceanStor all-flash storage system are
A. It supports clusters consisting of multiple controller enclosures to improve the availability of the
storage system, B. Interconnect I/O modules shorten failover time when a controller fails to provide
better reliability, as compared with common I/O modules, and D. When a controller fails, l/Os of the
faulty controller are redirected to another controller The host is unaware of the fault and services
remain running properly. Statement C. Standard I/O modules shorten failover time when a controller
fails to provide better reliability, as compared with interconnect I/O modules is false.
Which statements are true about RAID 2.0+? (Select All that Apply)
AC
A bank purchases a new storage device. During the RAID level configuration, the bank requires that
data reliability be improved and parity data be stored on different disks. Which RAID levels can meet
the requirements? (Select All that Apply)
BD
Explanation:
RAID 5 and RAID 6 can meet the requirements as they both improve data reliability by storing parity
data on different disks. RAID 0 and RAID 3 do not store parity data on different disks, so they would
not meet the bank's requirements.
Which statements are true about the SAN network? (Select All that Apply)
BC
Explanation:
The IP SAN can use the existing IP network, and it supports the iSCSI protocol. The FC SAN must be
configured with dedicated iSCSI HBAs for servers, and the FC HBA used by the FC SAN cannot convert
SCSI packets into FC packets.
What are the main functions of the business continuity solution? (Select All that Apply)
ACD
Explanation:
The main functions of the business continuity solution are to minimize the impact on the business
service, ensure zero data loss and zero service interruption, and improve the utilization rate of the
disaster recovery equipment. Predicting the disaster occurrence accurately is not a function of the
business continuity solution.
Which of these are O&M standard systems? (Select All that Apply)
AC
Explanation:
International Organization for Standardization 2000 (ISO2000) and Information Technology
Infrastructure Library (ITIL) are O&M standard systems. Institute of Electrical and Electronics
Engineers (IEEE) and Storage Networking Industry Association (SNIA) are not O&M standard systems.
A company purchased DAS devices to store files and service data at the startup stage. With the
increase of service volume and diversity, which problems may occur? (Select All that Apply)
ABD
Explanation:
With the increase of service volume and diversity, problems such as difficulty in expanding the
capacity of the DAS architecture, data and materials being scattered on different devices and hard to
be managed in a centralized manner, and hard to be searched for may occur. Adding more servers to
share the DAS storage is not an issue.
Which of the following statements correctly describe the improvements of SAS technology compared
to SCSI? Select All that Apply.
BD
Explanation:
SAS technology offers full duplex transmission of data and higher throughput than SCSI, which makes
it more cost-effective and efficient. SAS technology does not offer half duplex transmission of data.
Which statements are true about distributed storage? (Select All that Apply)
ACD
Explanation:
Distributed storage systems are designed to support horizontal scaling, which means adding more
nodes to the system to increase both computing capability and storage space. This enables the
system to handle large amounts of data and large numbers of users. Distributed storage systems also
support storage resource pooling and virtualization, which allows for efficient use of storage
resources and easy management of storage.
Which of the following are the data transmission rates that can be configured on the FC ports on the
FC switch in FC SAN given that your cable and SFP supports it? (Select All that Apply)
ABD
Huawei OceanStor hybrid flash storage is used as an example. Which statements are true about IP
address failover? (Select All that Apply)
BD
Explanation:
A failover group is a combination of ports that are used for IP address failover in a storage system,
and IP address failover ensures service continuity and improves the reliability of paths for accessing
file systems. IP address failover applies to all storage network architectures, not just IP SAN. Fallback
means that the standby port takes over services when the active port fails, and then the active port
takes over services again after it recovers.
Which statements are true about HyperMetro? (Select All that Apply)
ABD
Explanation:
HyperMetro allows the local and remote sites to run services at the same time, and a quorum server
must be configured. Additionally, automatic switchover upon storage faults is supported. HyperClone
can be configured for storage devices of different models and versions.
As the new storage administrator, you are tasked with the procurement of a new batch of SSD drives
to replace the older drives that has reached the end of life. You have the option of SLC, MLC and TLC
SSD. Which of the following will be your choice with a limited budget and medium level of reliability
concerns? (Select All that Apply)
CD
Explanation:
When choosing between different types of SSDs, the main factor to consider is the trade-off between
cost and reliability. SLC (Single-Level Cell) SSDs are the most reliable and have the longest lifespan,
but they are also the most expensive. TLC (Triple-Level Cell) SSDs are less reliable than SLC SSDs, but
they are also less expensive. MLC (Multi-Level Cell) SSDs are a good balance between cost and
reliability, they are more affordable than SLC SSDs and more reliable than TLC SSDs.