Questions for the API-936 were updated on : Nov 21 ,2025
[Acceptance Criteria]
Which of the following is a valid acceptance criterion for cold crushing strength of castable used in
erosive service?
C
[Curing and Dryout]
In accordance with TR 980, when curing a high-purity, low-cement castable for a high-temperature
unit, which of the following sequences ensures minimum cracking risk?
B
[Inspection and Testing Requirements]
Which of the following is a correct condition for gunned material test panels used for CCS and PLC
testing?
B
[Material Requirements]
Which of the following conditions must be met for test results from trial mixes of low cement
castables to be accepted for qualification?
A
[Inspection and Testing Requirements]
Abrasion resistance of a material is reported as loss of:
C
[Material Requirements]
The best definition for creep is:
A
[Installation Procedures]
Before application of a curing compound the hydraulic bond castable surface shall not be allowed to
air dry longer than:
A
[Inspection and Testing Requirements]
What abrading media is required in the ASTM C-704 abrasion-resistant test?
C
[Inspection and Testing Requirements]
What is the ASTM test designation for cold crush strength?
D
[Installation Procedures]
Which party or individual is responsible for submitting a dryout procedure for a new lining?
A
[Inspection and Testing Requirements]
For as-installed testing in casting applications, what is the minimum number of cast samples required
by each mixing crew per material per shift?
B
[Responsibilities and Qualifications]
Which of the following is the inspector responsible for?
A
[Responsibilities and Qualifications]
The installation contractor is required to secure an advance agreement that concerns all the
installation details from the:
C
[Installation Procedures]
If application of hydraulic bonded or chemical setting refractory is interrupted, the refractory lining
shall be:
C
[Inspection and Testing Requirements]
A change in the length of a specimen measured before and after heating to a specific temperature is
referred to as:
B